Global Door & Window
Project Solution Provider
Home / All / Windows / Aluminum Casement Windows / BC-130 Heavy-Duty Hurricane-Resistant Aluminum Casement Window with Integrated Screen

BC-130 Heavy-Duty Hurricane-Resistant Aluminum Casement Window with Integrated Screen

BC-130 Heavy-Duty Hurricane-Resistant Aluminum Casement Window with Integrated Screen
Share
CategoriesAluminum Casement Windows
BrandBLOSSOM CHEER Door And Window Project Manufacturer
Product SpecificationsBC-130
ModelBC-110
Product TypeThermal Break Aluminum Casement Window
Frame Depth110–115 mm
Project ServiceODM / Custom Project Support
SampleAvailable
Production Time15-25 Days
FOB portGuangzhou
Terms of PaymentL/C, D/A, D/P, Western Union
Detail Information

BC-130 heavy-duty hurricane-armor integrated screen casement window system

BC-130

Heavy-Duty Hurricane-Armor Integrated Screen
Casement Window System

Extreme Wind-Load Protection
Engineered for Coastal Landmark Facades

5.0kPa+ Wind
Resistance
3.0mm Profile
Walls
130mm Frame
Depth
#304 Security
Screen
Closed-Section Glazing Bead
Closed-Section Glazing Bead
Die-Cast Frame Corner Cleat
Die-Cast Frame Corner Cleat
CMECH (USA) Heavy-Duty Minimalist Handle
CMECH (USA) Heavy-Duty Minimalist Handle

BC-130 Core Physical & Structural Specification Matrix

The following engineering metrics are verified against GB/T 7106, GB/T 8484, ASTM, and AAMA standards, confirming the BC-130's structural resistance under extreme wind and storm conditions.

Engineering Metric Performance Value Reference Standards
Frame Depth 130 mm structural depth, with a 46 mm exterior face and 26 mm interior face GB/T 8478-2020 / AAMA 101
Sash Profile Dimensions 77.9 mm sash width / 78.05 mm sash depth, engineered for heavy-duty load transfer Industrial heavy-load profile standard
Alloy & Wall Thickness 6063A-T5 ultra-high-precision aluminum with 3.0 mm main load-bearing profile walls throughout ASTM B221 / EN 755-2
Thermal Break Barrier Rongtai glass-fiber-reinforced PA66GF25 nylon thermal-break strips with vertical-isotherm design GB/T 23615.1 / EN 14024
Wind Load Resistance Class 9 (P3 ≥ 5.0 kPa), engineered for direct super-typhoon exposure GB/T 7106 / ASTM E330
Water Penetration Resistance Class 4 (350 Pa ≤ ΔP < 500 Pa) without leakage or stormwater backflow GB/T 7106 / ASTM E331
Air Permeability Class 7 (q1 ≤ 0.5 m³/(m·h) / q2 ≤ 1.5 m³/(m²·h)) GB/T 7106 / ASTM E283 Class 4
Acoustic Sound Insulation 25–30 dB with standard insulated glazing; laminated high-performance configurations can reach 35 dB+ GB/T 8485 / ASTM E90
Standard Glazing Unit Taiwan Glass float panes: 5G + 27A + 5G insulated glass with reinforced one-piece bent spacer Automotive-grade raw-glass processing standard
Glazing Bead Options Beveled or square insulated-glass beads for 5–15 mm glass, plus laminated-glass beads for 8–15 mm glass Multi-specification engineering bead system
Security Screen Specification #04 high-airflow #304 stainless-steel 18-mesh security screen with anti-drop tether and impact-safe corner guards ASTM A555 / 304 Stainless Steel
Gasket & Sealing System Jiangyin Haida automotive-grade EPDM gaskets with interior and exterior sealant-free glazing assembly ISO 3934 / ASTM C864

Heavy-Duty Transmission Hardware & High-Security Locking Systems

Integrating CMECH heavy-duty transmission hardware with precision-cast carbon-steel gearboxes and Nano-Blue anti-corrosion coatings for high torsional strength, reliable compression sealing, and long coastal service life.

BC-130 heavy-duty casement window transmission and locking system
CMECH (USA) Heavy-Duty Minimalist Handle

CMECH (USA) Heavy-Duty Minimalist Handle

A reinforced 10 mm drive spindle—substantially heavier than conventional 7 mm shafts—doubles torsional resistance for smooth, long-term control of oversized sashes.

Precision-Cast Carbon-Steel Transmission Gearbox

Precision-Cast Carbon-Steel Transmission Gearbox

Precision-cast carbon-steel gears, corrosion-resistant Nano-Blue treatment, and stainless locking cams provide durable wear resistance in salt-laden coastal environments.

Multi-Point Sliding Compression Locking Mechanism

Multi-Point Sliding Compression Locking Mechanism

Perimeter locking cams translate the handle's motion into uniform EPDM gasket compression, improving wind resistance, acoustic damping, airtightness, and anti-pry security.

Stainless Steel Anti-Drop Safety Cable

Stainless Steel Anti-Drop Safety Cable

Multi-strand stainless safety cables restrain the sash under extreme loading.

Anti-Collision Corner Guard

Anti-Collision Corner Guard

Flexible R10 corner guards reduce everyday collision and injury risks.

Micro-Structure Driven Scenario Configuration & Engineering Matrix

Deriving from 3.0mm ultra-heavy profile walls, modular hurricane-reinforced mullions, interlocking glazing beads, and 27A insulated-glass pockets, BC-130 provides EPC contractors and architects with extreme-condition specifications for coastal towers, large-span balcony enclosures, and island resorts.

BC-130 Extreme-Condition Project Configurations

BC-130 scenario configuration 1

Coastal Typhoon, Large-Span Balcony & Island Resort Configurations

Configure reinforced mullions, glazing make-up, CMECH hardware, drainage, and integrated security screening around project span, glass weight, coastal exposure, and design wind pressure.

Verified Project & Laboratory Evidence

Recommended Styles

Explore casement window designs from our style library for architectural inspiration. Confirm BC-130 window configurations, opening arrangements and dimensions with our team.

Available Colors & Finishes

Explore aluminum alloy profile colors and finishes from our finish library. Confirm coating suitability for the BC-130 window system and the final color with an approved project sample.

B2B Engineering Submittal & Technical Specification Download Hub

Access BC-130 engineering specifications, AutoCAD installation details, reinforced-mullion and interlocking-bead nodes, certified laboratory reports, and 24-hour 5000Pa+ structural load-review support for global developers, EPC contractors, importers, and lead architects.

Review
  • 加载中···
  • Start Your Inquire
    • *Email
      *Full Name
      *Phone

Project Technical Alignment: Initiate Your Entrance System Shop Drawing Deepening & Code Verification

Our engineers will review your drawings, thermal breaks, wind loads, and security specs to deliver a compliant localized submittal package matching your project constraints.

Empower Your Vision Unlock Expert Support & Proven Solutions.

Engineering-Ready Digital Resources

Gain immediate access to our high-precision CAD node library and BIM models. We translate complex architectural visions into manufacturable reality, ensuring your design phase is backed by proven technical data.

BIM/CAD LibraryProject Deep-Dive

Zero-Profit Logistics & Local Execution

Eliminate shipping markups with our transparent, factory-cost logistics. From metropolitan hubs to remote island nations, we coordinate the "Last Mile" through a network of vetted installation nodes and professional handlers.

Direct Freight CostGlobal Service Nodes

Versatile Project Excellence Since 2010

Decades of field-tested mastery across diverse climates and cultures. We understand the specific structural demands of North American high-rises as deeply as the anti-corrosion needs of South Pacific coastal villas.

Climate-Adaptive Design150+ Global Projects

Verified Performance & Global Compliance

We document every detail of quality. Access our library of domestic lab tests, EU eco-certifications, and track our ongoing US NAFS performance testing.

Domestic Lab VerifiedEU Eco-CertifiedUS NAFS (In Progress)

24h Engineering Response Protocol

Connect directly with our 8-person core task force. Within 24 hours, you receive more than a quote—you get a preliminary structural assessment and a strategic execution roadmap for your inquiry.

Rapid AssessmentDirect Expert Access

[Partner Bonus] Exclusive Asset

Submit your inquiry today, and our team will share an exclusive "Industry-Specific Success File" featuring real-world photos and node details of completed projects similar to yours.

Submit your inquiry, and our experts will review your requirements and respond within 1 business day.

Project Information

to

Physical Dimensions & Alignment

Note: Please account for plaster layer if using Wall-to-Wall.
Function AreaHeightWidthWall Thk.QtyAcoustic Req.Fire-RatedEntry ControlPre-wiringGlass Solution

Logistics & Asset Management

Do you need each door/window to have a Laser-Etched QR Code?

Remarks & Attachments

PDF, drawings, photos, or schedules
    subscription